 rev. page page date date 1 of 4
06/2008
PART NUMBER: VSK-S3-XXU series
DESCRIPTION: ac-dc converter
features
* * * * * * * * * * universal input 85~264 Vac/ 110~370 VDC encapsulated, compact case high efficiency surface mounting technology 100kHz fixed frequency fixed output voltage thermal shutdown output short circuit protection low output ripple and noise isolated output
model
VSK-S3-3R3U VSK-S3-5U VSK-S3-9U VSK-S3-12U VSK-S3-15U VSK-S3-24U
output (Vo1/Io1) 3.3V/700mA 5V/600mA 9V/330mA 12V/250mA 15V/200mA 24V/125mA
output (Iomax/T) 900mA/60S 750mA/60S 450mA/60S 330mA/60S 250mA/60S 160mA/60S
power max. 2.3 W 3.0 W 3.0 W 3.0 W 3.0 W 3.0 W
ripple & noise max. 30 mVp-p 30 mVp-p 30 mVp-p 30 mVp-p 30 mVp-p 30 mVp-p
efficiency (%) 63 72 74 76 76 78
INPUT
parameter input frequency input voltage input current inrush current leakage current conditions/description output power derated from 85-90 VAC AC input of 110 VAC AC input of 230 VAC measured at 110 VAC at full load, cold start measured at 220 VAC at full load, cold start none min 47 85 110 nom (50~60) max 440 264 370 65 30 10 20 units Hz VAC VDC mA mA A A
OUTPUT
parameter voltage tolerance line regulation load regulation rise time hold-up time conditions/description 3% for 3.3V output 10% to 100% Vin = 230 V ac min -2% -3% -5% nom max +2% +3% +5% 100 units
50
mS mS
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
rev. page date 2 of 4
06/2008
PART NUMBER: VSK-S3-XXU series
DESCRIPTION: ac-dc converter
PROTECTION CIRCUIT
parameter over temperature over voltage conditions/description 150 C max. chip lock up
GENERAL
parameter operating temp. storage temp. case temp. power derating humidity storage humid. isolation voltage (HI-POT) MTBF RoHS case material safety EMC 1 warranty conditions/description min -25 -40 nom max 70 105 95 units C C C %/C RH RH
above 55C
2
95% non-condensing 20% 90% applied for 1 minute primary to secondary, 500 Vdc @ 100 M 3000 VAC at 25C 200,000 hours yes UL94V-0 IEC60950, approved to EN60950, UL60950 IEC/EN 61000-4-2 level 4 (8kV/15kV), IEC/EN 61000-4-2, IEC/EN 61000-4-4 level 3 (2kV), IEC/EN 61000-4-4 level 4 (4kV), IEC/EN 61000-4-5 level 3 (1kV/2kV), IEC/EN 61000-4-5 level 4 (2kV/4kV) standard warranty length 2 years
TEMPERATURE VS LOAD
INPUT VOLTAGE VS LOAD
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
rev. page date 3 of 4
06/2008
PART NUMBER: VSK-S3-XXU series
DESCRIPTION: ac-dc converter
TYPICAL EFFICIENCY CURVE
TYPICAL EFFICIENCY CURVE
Connect Oscillograph probe Fuse C3 C1 Copper sheet
C2
Load
3
25.4mm 25.4mm
TYPICAL EFFICIENCY CURVE
L
* FUS E * NT C L
M OV +V0
C1 +
C2
Tvs RL
* F USE * NT C L
NF C6 C8 C7
L
MO V
+V0
C1 C2 Tvs + RL
C3 +
22 26
C3 +
22 26
-V0
N
- V0
N
N
N
Figure1 Figure 2 VSK-S3 EMC Application Figure EXTERNAL CAPACITORS TYPICAL VALUE(Unit: F) model VSK-S3-3R3U VSK-S3-5U VSK-S3-9U VSK-S3-12U VSK-S3-15U VSK-S3-24U
Note! 1. Output filtering capacitors C1, C3 is electrolytic capacitors, It is recommended to use high frequency and low impedance electrolytic capacitors. For capacitance and current of capacitor please refer to manufacture's datasheet. Voltage derating of capacitor should be 80% or above. C2, C4 is ceramic capacitors , it is used to filter high frequency noise. TVS is a recommended component to protect post-circuits (when converter fails). 2. MOV is required for VSK-S3 models. Model: 471KD05, it is used to protect the device under surge. 3. It is recommended to connect FUSE, the parameter is 0.5A/250V slow blow. External input NTC is recommended to use D -14 or 10/2W wire-round resistor. 4. If EMC performance is required, recommended to add "EMC filter" at the input end(see figure 2) C6:X capacitor, recommended parameter 0.1uF/275V; C7,C8:Y capacitor, recommended parameter 220pF/2000V; NF: common model choke, recommended inductance is about 10mH-30mH. 5. Terminals 22 and 26 are internal rectification and filtering terminals. To protect the models further, it is recommended to connect an electrolytic capacitor C3 (it is recommended to be 4.7uF/400V). If operation voltage of the module is between 160~264VAC, C3 can be removed.
C1 150 150 150 150 150 150
C2 0.1 0.1 0.1 0.1 0.1 0.1
C3 4.7/400V 4.7/400V 4.7/400V 4.7/400V 4.7/400V 4.7/400V
TVS P4KE6.8A P4KE6.8A P4KE12A P4KE20A P4KE20A P4KE30A
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
37.00 1.457
REV. A
DESCRIPTION NEW DRAWING
DATE 4/2/2008
15.00 0.591
4.10 0.161 (TYP)
0.80 0.031 (7 PLCS) 3.26 0.128 (2 PLCS) 2.61 0.103 (TYP)
8.34 0.328
1
3
13
23.00 0.906
17.78 0.700
SCALE: 1:1 26 22 16 14
3.26 0.128 (2 PLCS) 13.42 0.528
BOTTOM VIEW
5.08 0.200 (TYP)
NOTE: PIN DIAMETER: 0.800.05mm WEIGHT: 25g TOLERANCE: 0.5mm UNLESS OTHERWISE SPECIFIED
2.54
RECOMMENDED FOOTPRINT TOP VIEW
RoHS
1.2 0.047 (7 PLCS)
26
22
16
14 20050 SW 112th Ave. Tualatin, OR 97062 FOOTPRINT DETAILS Phone: 503-612-2300 PIN FUNCTION 800-275-4899 Fax: 503-612-2383 1 L Website: www.cui.com 3 N TITLE: REV: SWITCHING POWER SUPPLY 13 NC A 14 -Vo PART NO. UNITS: VSK-S3-XXU 16 +Vo MM [INCHES] 22 +Vin(DC) APPROVED BY: SCALE: DRAWN BY: ZRJ 2:1 26 -Vin(DC) NC: no connection
1
3
13
PC FILE NAME:
VSK-S3-XXU
COPYRIGHT 2008 BY CUI INC.


▲Up To Search▲   

 
Price & Availability of VSK-S3-15U